Manual · Gold standard

UnoMeter™ Safeti™ PlusThe trusted market leading standard with clinical documentation and superior effectiveness in daily use

A closed hourly diuresis system combining precise measurement, documented infection control with solutions on how to improve effectiveness in daily use.

Hourly Diuresis Monitoring System

Infection Prevention

The UnoMeter™ Safeti Plus Hourly Diuresis Monitoring System helps to prevent retrograde urinary tract infections*. In vitro study results have demonstrated that the system helps to prevent retrograde infection more effectively than traditional competitor devices.

In addition, the UnoMeter™ Safeti Plus has been designed to save nursing time and provide accurate urine measurement for all patients, even for low volumes, for various bed types and the mesurement is protected during transportation.

Chamber and non-return valve detail

The design of UnoMeter™ Safeti Plus with the topmounted chamber, High performance filters and KombiKon™ helps to minimize the risk of retrograde infection*

1
Integrated filter illustration

The integrated filters delivers a documented 99,9% barrier against bacteria and virus* supporting system integrity

2
KombiKon™ connector

KombiKon™ provides a documented barrier against bacterial entry for up to 10 sample collections*

UnoMeter Safeti Plus hourly diuresis monitoring system

* Please refer to list of clinical evidence

Optimized Nursing

Optimized Nursing

UnoMeter™ Safeti Plus has been developed to save nursing time and provide caregivers with the confidence of reliable urine measurement. The system has been designed with features to help optimize nurses' experience so they can focus on their patients.

Effectiveness and safety for caregiver and patient

Unimpeded flow for effective and accurate measurement

1
Double lumen tube

Double lumen tube designed to secure continuous flow and accurate measurement

2

Documented accurate measurement also at low volumes due to continuous flow*

3

Non-return-valve in collection bag supports prevention of urine backflow to the chamber

4
Hydrophobic filter material

Filter in the open/close function and emptying bag: The filter is hydrophobic, which supports unimpeded flow, also in wet conditions

Safe use for patient and caregiver

5

Non-return valve at KombiKon™ connector protects against urine reflux during and after transportation and no risk of not un-clamping the tube after transportation

6

The KombiKon™ urine sampling port with transparent inspection window allows observation of urine build up to enable less waiting time and a fresh urine sample

7

The UnoMeter™ Safeti™ Plus does not lose the measurement in the chamber during transportation if placed with the front facing up

UnoMeter Safeti Plus hourly diuresis monitoring system
In vitro study

The UnoMeter™ Safeti Plus Difference

The UnoMeter™ Safeti Plus helps to prevent retrograde infection more effectively than traditional urine measuring devices with a front-mounted chamber*

An in vitro study compared the UnoMeter™ Safeti Plus and two front-mounted devices in preventing bacterial migration from the collection bag to the measuring chamber2

Percentage of Samples with Bacteria Growth

DeviceAfter 2 daysAfter 4 daysAfter 7 days
Urine meter 175%100%100%
Urine meter 2100%100%100%
UnoMeter™ Safeti Plus0%0%0%

In vitro study: four samples were tested for each device and taken at set time intervals to show whether there was bacteria growth (n=4)

Bacterial migration illustration

Summary of study results*, ²

The UnoMeter™ Safeti Plus demonstrated better infection control compared to the front-mounted systems

  • In both front-mounted devices, contamination progressed into the measuring chamber after 2 days. The UnoMeter™ Safeti Plus showed no progression of bacteria after 7 days
  • The study results demonstrated that the UnoMeter™ Safeti Plus contains contamination within the collection bag and does not allow bacterial migration to the measuring chamber or catheter

* Please refer to list of clinical evidence

In vitro bacterial culture
In vitro bacterial culture

The risk of Catheter Associated Urinary Tract Infections (CAUTI)

Monitoring hourly diuresis is more than just a measurement. It is essential for detecting impaired fluid balance, renal insufficiency, or possible infections of critically ill patients.

While important to perform, catheterbased urine measurement can lead to CAUTI and additional treatment complications.

The prevalence of CAUTI

CAUTIs are the most common nosocomial infections in hospitals, accounting for >40% of all institutionally acquired infections.5

CAUTIs result in

  • Increased morbidity and mortality
  • Increased length of hospital stay by 2-4 days
  • Excess health care cost of $400 to 500 million per year in the US
UnoMeter Safeti Plus hourly diuresis monitoring system
Intended use

Hourly diuresis monitoring for precision urine output measurement

Specifications
Approved use
Up to 7 days
Meter chamber
40 ml high precision inner chamber + 500 ml. precision chamber
Bag volume
2,000 ml (3,000 ml via Exchange Bags)
Sample port
KombiKon™ needle-free with documented barrier against bacterial entry for up to 10 sample collections

CE-marked medical device. For professional use only. Refer to instructions for use.

Clinical evidence

Research relevant to UnoMeter™ Safeti™ Plus

Explore the published studies and independent reports that support this product and its technologies.

View all clinical evidence
2011

In vitro test of ascending contamination in different urine meter systems

Frimodt-Møller N., Corneliussen L. · Dept. for Microbiological Surveillance Research

Available on request
2009

Closed System Study Test Report

Ashman P. · Surgical Materials Testing Laboratory, Princess of Wales Hospital

Available on request
2005

In vitro test of different urine-meters in an experimental bladder-drainage model: prevention of ascending contamination depends on construction of the urine-meter

Frimodt-Moller N., Corneliussen L. · British Journal of Infection Control

2004

Performance of KombiKon needle free sample port

Tvede M. · Dept. of Clinical Microbiology, Rigshospitalet, University of Copenhagen

Available on request
Next steps

Interested in UnoMeter™ Safeti™ Plus?

Contact our team for pricing, samples, or clinical evaluation support.